NKZ with agitator
Voltage 3~ 400V/50Hz
All pumps in this series provide
very smooth passage of sandy
earth and slime. A forcibly cooled
motor ensures long and continuous
pump operations exposed to the air.
Standard Accessories:
-
1 Cable 20m
-
1 Threaded Flange
|
|
|
Model
|
Bore
|
Motor
output
kW |
Nominal
current
A
400V |
Voltage
50HZ |
Max
head
m |
Max
capacity
l/min |
Starting
method |
Dry
weight
kg |
Max. solids
passage
mm |
Max. water
depth
m |
Cable
length
m |
NKZ3-C3 |
80 |
2,2 |
5,1 |
3-phase |
12,6 |
930 |
d.o.l. |
91 |
30 |
30 |
20 |
NKZ3-D3 |
80 |
3,7 |
8,0 |
3-phase |
17,0 |
1540 |
d.o.l. |
100 |
30 |
30 |
20 |
| NKZ-80H |
80 |
5,5 |
12,1 |
3-phase |
24,9 |
1530 |
d.o.l. |
114 |
20 |
30 |
20 |
NKZ-100H |
100 |
11 |
22,0 |
3-phase |
28,8 |
2440 |
d.o.l. |
192 |
20 |
30 |
20 |
| dry weight of the pump without cable |
|
| Item |
Discharge bore (mm) |
80 100 |
Pumping
fluid |
Type of fluid |
Sludge, slurry, liquids
containing sandy mud |
| Liquid temperature |
0 ~ 40°C |
| Pump |
Components |
Impeller |
Open type |
| Shaft Seal |
Double mechanical seal |
| Bearings |
Shielded ball bearings |
| Materials |
Impeller |
Chromium iron casting |
| Casing |
Grey iron casting |
| Suction plate |
Grey iron casting
Chromium iron casting |
Shaft seal
(mechanical seal) |
Silicon Carbide in oil bath |
| Motor |
Type, Poles |
Dry-type submersible
induction motor, IP68,
4poles, 1500 r.p.m. |
| Insulation |
Class E, B |
| Phase / Voltage |
Three-phase, 400V |
| Motor Protector (built-in) |
Circle thermal cut-out |
| Lubricant |
Turbine Oil (ISO VG32) |
| Materials |
Frame |
Grey iron casting |
| Shaft |
Stainless Steel EN-X30Cr13 |
| Cable |
Rubber, H07RN-F |
| Discharge Connection |
Hose coupling |
|

|
|
| |
|
Dimensions in mm
| Τύπος |
d |
A |
Α1 |
B |
B1 |
D |
Η |
W1 |
| NKZ3-C3 |
80 |
467 |
405 |
371 |
249 |
370 |
664 |
225 |
| NKZ3-D3 |
80 |
467 |
405 |
371 |
249 |
370 |
664 |
225 |
| NKZ3-80H |
80 |
491 |
430 |
387 |
264 |
401 |
754 |
220 |
| NKZ3-100H |
100 |
547 |
486 |
422 |
284 |
414 |
841 |
240 |
W1 = continuous running water level
|
|
|